Astronics Test Systems
<id>,<crc><lf>
Where:
<id>
CH01 through CH32, PG0 and PG1.
<crc>
The CRC value.
Error Address Save File Format
The Error Address results are saved in the following format:
<header><line feed>
<step>,<offset>,<pma>,< data><line feed>
Where:
<header>
“STEP,OFFSET,PMA,RECORD DATA”
<step>
Step number of the error.
<offset>
Pattern number.
<pma>
Pattern Memory Address.
<data>
Record memory.
Record Index Save File Format
The Record Index results are saved in the following format:
<header><line feed>
<step>,<offset><line feed>
Where:
<header>
“STEP,OFFSET”
<step>
Step number of the error.
<offset>
Record memory offset where the results are saved.
Record Data Save File Format
The Record Data results are saved in the following format:
<header><line feed>
<step>,<offset>,<data><line feed>
Where:
<header>
“STEP,OFFSET,RECORD DATA”
<step>
Step number of the error.
<offset>
Pattern number.
<data>
Record Memory contents.