Publication No. 980938 Rev. K
Model T940 User Manual
Astronics Test Systems
Soft Front Panel Operation 5-115
Transition
Description
Soft Front Panel Control
last step/stop
(idle finish
mode)
Sequence completes step
with last step flag true or
stop command. Finish
Mode set to Idle
•
Set
Finish Mode
to “Idle”
•
Enter step number and
depress
Execute
command
button.
•
If sequence is still active,
depress the
Stop
command
button.
last step/stop
(standby finish
mode)
Sequence completes step
with last step flag true or
stop command. Finish
Mode set to Standby
•
Set
Finish Mode
to “Standby”
•
Enter step number and
depress
Execute
command
button.
•
If sequence is still active,
depress the
Stop
command
button
halt
Halt the active sequence.
•
Make sure the
Halt Mode
is
not set to “Disabled”
•
Depress the
Halt
command
button. If sequence was
active,
Halt LED
should be red
(halted). If sequence was not
running,
Halt LED
should be
green (armed).
resume/single
step
Halt resume or single step
While in HALT state:
•
Depress
Resume
command
button to resume.
•
Depress
Halt
command button
to single step.
pause
Pause the primary
sequence
No control to manually pause the
primary sequence.
resume
Pause resume
While in PAUSE state:
•
Depress
Resume
command
button to resume.
Execute Panel Indicators
There are eleven indicators that display the current sequencer status. These
indicators are updated every 50 ms.
Idle LED
When green, indicates that the sequencer is in the IDLE state.
The relevant VXI
plug&play
API function is:
•
tat964_querySequencerStatus
Active LED
When green, indicates that the sequencer is in the ACTIVE state.