Publication No. 980938 Rev. K
Model T940 User Manual
Astronics Test Systems
Soft Front Panel Operation 5-111
received).
The selections for this pull-down control are:
Table 5-83: Handshake Modifier Settings
Setting
Resume Modifier
None
No modifier, resume on ‘Resume Signal” only
Pattern Delay 1
Pattern Delay 1 timer
Pattern Delay 2
Pattern Delay 2 timer
Pattern Timeout
Pattern timer (PTO also set)
The relevant VXI
plug&play
API function is:
•
tat964_setSequenceHandshake
Waveform Properties
The waveform logic allows the user to enable up to six waveforms per sequence
step (see
Chapter 5
). Waveform 1 through Waveform 4
have to be enabled per sequence step to replace the timing signals they are
paired with. Waveforms 5 and 6 are dedicated and do not need to be enabled.
Waveform1 – Waveform4
This control allows the user to enable/disable the specific waveform number.
The relevant VXI
plug&play
API function is:
•
tat964_setSequenceWaveform
Waveform Table
This numeric control allows the user to program the waveform table for the
sequence step. Numeric values can range from Waveform Tables 1 through 16.
The relevant VXI
plug&play
API function is:
•
tat964_setSequenceWaveform
Phase Trigger Properties
The phase trigger logic allows the user to select the phase trigger signal source
for the four phases between the “System Clock” and the “Pattern Clock (PCLK)”.
In “System Clock” mode, another Phase is output for each System Clock. In
“Pattern Clock” mode, another Phase is output for each Pattern Clock, which
results in the Phase output rate being at a multiple of the System Clock period if
CPP>1 (PER
PCLK
= PER
SCLK
* CPP).
The relevant VXI
plug&play
API function is:
•
tat964_setSequencePhaseTrigger