Model T940 User Manual
Publication No. 980938 Rev. K
Advanced Topics 8-6
Astronics Test Systems
Signal
When needed
Driver
Disable
If programmed to do so on each Sequencer, a channel fault
which occurs on the Master or any connected/coupled
Sequencer will disable all of the channel drivers.
Static Pulse
Couples the Static Stimulus/Response Pulse from the
Master to all connected/coupled sequencers. It is only
needed if Static Mode is being used.
The signals above, which are desired for a DRS configuration,
must be
setup on the same
TRG buses on the Master and each coupled Sequencer.
Warning: Do not program the same TRG Bus for Sequencers which are not
a part of the DRS.
Step Record Mode
Step Record Mode is programmed in each Sequencer Step. On the SFP, it is
set on the Edit>Data Sequencer A/B>Sequence Steps panel.
The relevant VXI
plug&play
API and ARI functions are:
•
API: tat964_setSequenceRecordMode
•
ARI: AssignPtgResponseMode
Figure 8-4: Step Record Mode Control on Edit DSA Sequence Step Panel
As shown, the choices are:
•
None
•
Record Count
•
Record Error