Publication No. 980938 Rev. K
Model T940 User Manual
Astronics Test Systems
Soft Front Panel Operation 5-35
The relevant VXI
plug&play
API functions are:
•
tat964_setPauseTriggerReset
•
tat964_setHaltTriggerReset
•
tat964_setJumpTriggerReset
Configure Pulse Generator
Access this panel from the menu bar:
Config > Data Sequencer x> Pulse
Generator
(where “x” is the sequencer you wish to configure).
Figure 5-24: Configure Pulse Generator
Each data sequencer has a programmable pulse generator that can be routed to
the following signals:
•
Data sequencer System Clock
•
VXI TTLTRG
•
VXI ECLTRG
•
Front panel AUX
Resolution
This toggle control is used to program the pulse generator resolution to either 10
ns or 20 ns.
The relevant VXI
plug&play
API function is:
•
tat964_setPulseParameters
Mode
This pull-down control programs the pulse generator mode.