User Manual
KDC Series II DC Power Supplies
61
2. External Current Programming Using Resistance. The resistance coefficient for remote
current programming is 5k ohms/100% rated output with respect to pin 6 (ISO VP/IP RTN).
The programming current from PIN 5 (IP RES) is factory set for 1 milliamp. This yields a
coefficient of 1.0% of rated output current for each 50 ohms. If multiple switches or relays are
used to program different levels, make-before-break contacts are recommended. . See
Figure 5-5 for connection requirements.
From the CONTROL menu, set the CURRENT REF to EXTRES.
1
8
9
15
ANALOG I/O
VP/IP RTN 6
IP RES 5
0 - 5 KOHM
PROGRAM
R
11 IPROG 5V
Figure 5-5: Remote Current Programming Using Resistance
4. External Current Programming using an external current source. This is similar to the use of
a voltage source except the available current source is converted to a voltage source by using
an external resistor. If the current source is fixed, a variable resistor will result in a voltage
input to the RPI input proportional to the resister setting. See Figure 5-2
for connection
requirements.
From the CONTROL menu, set the CURRENT REF to EXT10V.
1
8
9
15
ANALOG I/O
14 ISO COM
CURRENT
SOURCE
R
11 IPROG 5V
Figure 5-6: Remote Current Programming Using a Current Source
Summary of Contents for KDC 100-100
Page 2: ......
Page 10: ......
Page 26: ...User Manual 16 KDC Series II DC Power Supplies Figure 3 1 Location of rear panel connectors ...
Page 33: ...User Manual KDC Series II DC Power Supplies 23 Figure 4 3 Front panel layout ...
Page 82: ......
Page 83: ...User Manual KDC Series II DC Power Supplies 73 Figure 6 1 DC Power Supply Block Diagram ...
Page 111: ...User Manual KDC Series II DC Power Supplies 101 Figure 8 2 Replaceable Fuse Locations ...