User Manual
KDC Series II DC Power Supplies
43
Configuration Control Modes.
Note that the control settings can be used to select one of four operating modes. The modes and
their impact on the user‟s ability to change settings on a unit are shown in Table 4-3. The control
mechanism used in each mode of operation is also indicated for reference. For more information
on multi-box configurations, see section 5.2.
Operating Mode
SET Display
Control
MASTER
Master unit
Requires controller to be
configured for stand-alone
operation.
VOLT
<set value>
CURR
<set value>
Voltage and current limit set
from front panel or over bus.
AUX AP
Auxiliary, auto parallel
Requires controller
configured for
–AUX.
VOLT
N/A
CURR
EXT
Current controlled by MASTER
unit. Voltage same as
MASTER unit.
CURR REF: EXT5V
AUX AS
Auxiliary, auto series
Requires controller to be
configured for stand-alone
operation.
VOLT
EXT
CURR
N/A
Voltage controlled by
MASTER. Current tracks
MASTER unit.
VOLT REF: EXT10V
AUX AT
Auxiliary, auto tracking
Requires controller to be
configured for stand-alone
operation.
VOLT
EXT
CURR
<set value>
Voltage tracks MASTER.
Current limit set from front
panel.
VOLT REF: EXT10V
Table 4-3: Configuration Control Modes.
Note that the active configuration mode is saved when saving a setup to a non-volatile register. If
the firmware of the KDC power supply is updated in the field, it may be necessary to reset NVM
settings with the correct configuration setting. This can be done by changing the power on default
to RST, cycling the power, setting the unit up as desired, saving the new setup in REG0 and then
assigning REG0 as the power on setting. See 4.2.7 for details on using setup registers.
Note:
Switching modes between MASTER, AUX AS and AUX AT can be done by
changing the configuration setting only. Switching to AUX AP mode
however requires changes to the controller jumper settings. See section
5.2.1 for hardware configuration details.
Summary of Contents for KDC 100-100
Page 2: ......
Page 10: ......
Page 26: ...User Manual 16 KDC Series II DC Power Supplies Figure 3 1 Location of rear panel connectors ...
Page 33: ...User Manual KDC Series II DC Power Supplies 23 Figure 4 3 Front panel layout ...
Page 82: ......
Page 83: ...User Manual KDC Series II DC Power Supplies 73 Figure 6 1 DC Power Supply Block Diagram ...
Page 111: ...User Manual KDC Series II DC Power Supplies 101 Figure 8 2 Replaceable Fuse Locations ...