User Manual
36
KDC Series II DC Power Supplies
4.2.6
Transient Menu
The transient menu is used to program and execute user-defined output sequences. These output
sequences are defined as a sequential list of voltage and/or current settings that can be executed
in a time controlled manner.
Each step in these lists is assigned a sequence number ranging from #0 through #99. The
numbering determines the order in which each step is executed.
Each step can control the voltage setting, voltage slew rater, current setting, current slew rate and
dwell time. The dwell time determines how long the output dwells at the current step before
progressing to the next step. Dwell times can range from 1 msec up to 900000 secs.
Transient lists can be set up from the front panel or over the bus. The transient list can be saved
with the rest of the front panel settings in one of the setup registers. (See Register Menu).
ENTRY
DESCRIPTION
TRAN STATE
Indicates the status of the transient system. Available modes
of operation are:
IDLE
Transient system is in IDLE or inactive state. To
start a transient list, press the ENTER key while
on the TRAN STATE field. Note that the output
must be ON to run a transient program or an
error message will be displayed.
WTRIG
Transient system is armed and waiting for a
trigger event.
BUSY
Transient system is active. A transient list
execution is in progress.
COUNT
Sets the execution count for the transient system. A count of 1
indicates the transient will run 1 times. The count value can be
set with either voltage or current knob while the cursor is on
this field. The range for COUNT is from1 through 2E8. Values
above 200,000 will be displayed in floating point notation
(2E+05). Display resolution is limited when displayed as a
floating point number so it is not advised to use values above
2E5 from the front panel.
TRIG SOURCE
Indicates the trigger source for transient system. Available
trigger sources are:
IMM
Immediate mode. The transient is started from
the front panel using the ENTER key.
Summary of Contents for KDC 100-100
Page 2: ......
Page 10: ......
Page 26: ...User Manual 16 KDC Series II DC Power Supplies Figure 3 1 Location of rear panel connectors ...
Page 33: ...User Manual KDC Series II DC Power Supplies 23 Figure 4 3 Front panel layout ...
Page 82: ......
Page 83: ...User Manual KDC Series II DC Power Supplies 73 Figure 6 1 DC Power Supply Block Diagram ...
Page 111: ...User Manual KDC Series II DC Power Supplies 101 Figure 8 2 Replaceable Fuse Locations ...