Message String
Cause
Remedy
downloading data again. Successful
download may clear this error
condition.
-314
"Save/recall memory
lost"
User setup register
contents lost
Store setup in same register again.
-315
"Configuration memory
lost"
Hardware
configuration settings
lost.
Contact Argantix service department
at
to obtain
instructions on restoring configuration
data.
-330
"Self-test failed"
Internal error
Contact Argantix service department
at
-350
"Queue overflow"
Message queue full.
Too many message. Read status
using SYST:ERR query until 0, "No
Error" is received indicating queue
empty.
-400
"Query error"
Unable to complete
query.
Check programming manual for
correct query format and parameters
-410
"Query
INTERRUPTED"
Query issued but
response not read.
Check application program for correct
flow. Response must be read after
each query to avoid this error.
-420
"Query
UNTERMINATED"
Query incomplete.
Check for terminator after query
command.
-430
"Query
DEADLOCKED"
Query cannot be
completed
Check application program for
multiple queries
-440
"Query
UNTERMINATED"
Query incomplete.
Check for terminator after query
command.
1
"Output volt fault"
Output voltage does
not match
programmed value.
Load exceeds current limit and unit is
in Constant Voltage (CV) mode of
operation. Reduce load or increase
CL setting
Output voltage is driven above
programmed voltage by external
influence (Load, voltage kickback,
etc.)
2
"Current limit fault"
Current limit
exceeded.
Load exceeds current limit and unit is
in Constant Voltage (CV) mode of
operation. Reduce load or increase
CL setting
3
”Temperature fault”
Temperature of heat
sink too high
Reduce load. Ensure proper airflow
and exhaust clearance. Check fan(s)
for operation.
4
"External sync. error"
Could not sync to
external sync signal.
External sync signal missing,
disconnected or out of range.
5
"Initial memory lost"
Power on settings
could not be recalled.
Save power on settings again to
overwrite old content.
6
"Limit memory lost"
Hardware
configuration settings
lost.
Contact Argantix service department
at
to obtain
instructions on restoring configuration
data.
7
"System memory lost"
Memory corrupted.
Recycle power.
8
"Calibration memory
lost"
Calibration data lost.
Contact Argantix service department
at
to obtain
instructions on restoring calibration
Summary of Contents for KDC 100-100
Page 2: ......
Page 10: ......
Page 26: ...User Manual 16 KDC Series II DC Power Supplies Figure 3 1 Location of rear panel connectors ...
Page 33: ...User Manual KDC Series II DC Power Supplies 23 Figure 4 3 Front panel layout ...
Page 82: ......
Page 83: ...User Manual KDC Series II DC Power Supplies 73 Figure 6 1 DC Power Supply Block Diagram ...
Page 111: ...User Manual KDC Series II DC Power Supplies 101 Figure 8 2 Replaceable Fuse Locations ...