User Manual
52
KDC Series II DC Power Supplies
100V
75V
50V
25V
0V
1.000 2.000 3.000 4.000 5.000
150A
112.5A
75A
37.5A
0A
Limit Line (model specific)
= Voltage
= Current
#1 #2 #3 #4 #5 #6 #7 #8
Figure 4-6: Sample Transient Output Sequence
This output can be accomplished using the following transient list.
Step #
(data point)
Volt
VSlew
Current
CSlew
Dwell
1
0.00
MAX
75.00
MAX
0.100
2
50.00
125.00
100.00
MAX
0.900
3
75.00
MAX
50.00
200.00
0.250
4
25.00
66.67
50.00
MAX
0.750
5
25.00
MAX
105.00
MAX
1.000
6
50.00
MAX
100.00
MAX
0.800
7
20.00
MAX
100.00
MAX
0.200
8
50.00
MAX
100.00
MAX
1.000
Table 4-4: Sample Transient List