KDC Series II DC Power Supplies
11.2.3 Initial Setup
Nominal parameters for the DC Power supply in Mil-Std 704 test mode are as follows:
Output Voltage:
28V or 270V.
A setting outside these nominal values will disable the test and will prevent access to its Menu
screens.
11.2.4 Revision
The MIL704 option defaults to Revision E. The System is capable of performing Revision D tests
by changing the selection to Revision D.
All levels and timing in this document refers to Revision E. For Revision D refer to MIL-
STD-704D date 9/30/1980.
11.2.5 Tests Performed
STEADY STATE
Steady State Voltage test
Ripple test
TRANSIENT TEST
Transient Voltage low
Transient Voltage high
EMERGENCY TEST
Emergency Voltage minimum and maximum test
ABNORMAL TEST
Abnormal Voltage under
Abnormal Voltage over
11.2.6 Front Panel Entry
To perform a test from the keyboard, press the MENU key until the APPLICATIONS screen
appears. The APPLICATIONS screen is shown in Figure 11-3.
Figure 11-3: APPLICATIONS Screen
Select APPLICATIONS and press the ENTER key to display available applications. Use the
cursor to select the MIL704 entry as shown below.
Figure 11-4: MIL704 Menu
Summary of Contents for KDC 100-100
Page 2: ......
Page 10: ......
Page 26: ...User Manual 16 KDC Series II DC Power Supplies Figure 3 1 Location of rear panel connectors ...
Page 33: ...User Manual KDC Series II DC Power Supplies 23 Figure 4 3 Front panel layout ...
Page 82: ......
Page 83: ...User Manual KDC Series II DC Power Supplies 73 Figure 6 1 DC Power Supply Block Diagram ...
Page 111: ...User Manual KDC Series II DC Power Supplies 101 Figure 8 2 Replaceable Fuse Locations ...