User Manual
KDC Series II DC Power Supplies
95
8.3.1
Controller Module Removal / Replacement
If a fault is found that requires the replacement of the Controller Module (Assembly A3) follow the
following steps and refer to Figure 8-1 for the module locations:
1. Turn off the front panel On/Off switch. Remove any input power from the rear panel terminal
block by disconnecting or unplugging or otherwise disconnecting the AC input.
2. Allow time for any caps to discharge. This may take several minutes.
3. Remove the top cover.
4. Remove the screws along the bottom of the front edge that hold the front panel to the
chassis.
5. Remove the two nuts in the top corners of the front panel that hold the front panel to the
chassis.
6. Disconnect the system interface (40 pin) ribbon cable from the controller and disconnect the
power ribbon cable (10 pin). You can now remove the front panel assembly from the chassis.
7. Place the front panel assembly on a static free work surface.
8. Remove the two front panel knobs. Requires a small Allen wrench.
9. Remove 5 screws that hold the controller PCB assembly to the front panel. The controller
assembly can now be removed.
10. Any new controller that is installed must be correctly configured for the Voltage and Current
ranges of the KDC model. The voltage and current limits and the serial number stored in the
NVM configuration data of the controller must also be set correctly using the RS232C
interface. The KDCGUI may be used for this purpose if the authorized password is known.
Summary of Contents for KDC 100-100
Page 2: ......
Page 10: ......
Page 26: ...User Manual 16 KDC Series II DC Power Supplies Figure 3 1 Location of rear panel connectors ...
Page 33: ...User Manual KDC Series II DC Power Supplies 23 Figure 4 3 Front panel layout ...
Page 82: ......
Page 83: ...User Manual KDC Series II DC Power Supplies 73 Figure 6 1 DC Power Supply Block Diagram ...
Page 111: ...User Manual KDC Series II DC Power Supplies 101 Figure 8 2 Replaceable Fuse Locations ...