User Manual
KDC Series II DC Power Supplies
5
KDC 400-12
KDC 400-25
KDC 400-37
5
10
15
400
400
400
12.5
25
37.5
250 mV
250 mV
250 mV
2 V
2 V
2 V
2 V
2 V
2 V
KDC 500-10
KDC 500-20
KDC 500-30
5
10
15
500
500
500
10
20
30
250 mV
250 mV
250 mV
2 V
2 V
2 V
2 V
2 V
2 V
KDC 600-8
KDC 600-17
KDC 600-25
5
10
15
600
600
600
8.33
17
25
250 mV
250 mV
250 mV
2 V
2 V
2 V
2 V
2 V
2 V
2.1.6
Output Current
Current
Current Ranges:
See section 2.1.5
Current Programming:
Internal
Accuracy: 0.05 % S 0.1 % FS
Resolution: 0.025 % FS
Analog Input
Accuracy: 0.1 % S 0.2 % FS
Line Regulation:
< 0.1% of V Range
Load Regulation:
< 0.1% of V Range
Stability:
+/- 0.05% of set point after 8 Hrs. warm up at fixed line, load and
temp
2.2 Measurements
Measurement
Voltage
Accuracy: +/- (0.05% of R 0.1% of Full Scale)
Resolution: +/- (0.025% of Full Scale)
Current
Accuracy: +/- (0.1% of R 0.2% of Full Scale)
Resolution: +/- (0.025% of Full Scale)
Power
Accuracy: +/- (0.2% of R 0.3% of Full Scale)
Resolution: +/- (0.05% of Full Scale)
2.3 Environmental
Temperature Coefficient
Voltage Set Point: 0.02%/C of V Range
Current Set Point: 0.03%/C of I Range
Ambient Temperature
Operating: 0 to 50 C / 32 to 122 F
Storage: -40 to 75 C /-40 to 167 F
Humidity:
0 to 80 % RH, non condensing
Cooling:
Forced Air. Front, side and top air intake, rear exhaust.
Summary of Contents for KDC 100-100
Page 2: ......
Page 10: ......
Page 26: ...User Manual 16 KDC Series II DC Power Supplies Figure 3 1 Location of rear panel connectors ...
Page 33: ...User Manual KDC Series II DC Power Supplies 23 Figure 4 3 Front panel layout ...
Page 82: ......
Page 83: ...User Manual KDC Series II DC Power Supplies 73 Figure 6 1 DC Power Supply Block Diagram ...
Page 111: ...User Manual KDC Series II DC Power Supplies 101 Figure 8 2 Replaceable Fuse Locations ...