q
M4
— Selects the M4 marker parameter and opens the Markers second level
menu with M4 highlighted.
q
All Off
— Turns off all markers.
q
More
— Press to access additional marker functions:
q
M5
— Selects the M5 marker parameter and opens the M5 marker second
level menu with M5 highlighted.
q
On/Off
— Turns the selected marker on or off.
q
Edit
— Opens the selected marker parameter for data entry. Enter the
desired marker frequency using the keypad or Up/Down arrow key.
Select the
GHz
,
MHz
,
kHz
, or
Hz
soft key to accept the marker fre-
quency input.
q
Marker Freq To Center
— Makes the center frequency equal to the
frequency of the selected marker.
q
Peak Between M1& M2
— Places the selected marker at the frequency
with maximum amplitude value between marker M1 and M2.
q
Valley Between M1 & M2
— Places the selected marker at the fre-
quency with minimum amplitude value between marker M1 and M2.
q
Back
— Returns to the previous menu level.
NOTE: If markers M1 and/or M2 are off, the Peak and Valley functions above
are executed across the entire span.
q
M6
— Selects the M6 marker parameter and opens the M6 marker second
level menu with M6 highlighted.
q
On/Off
— Turns the selected marker on or off.
q
Edit
— Opens the selected marker parameter for data entry. Enter the
desired marker frequency using the keypad or Up/Down arrow key.
Select the
GHz
,
MHz
,
kHz
, or
Hz
soft key to accept the marker fre-
quency input.
q
Marker Freq To Center
— Makes the center frequency equal to the
frequency of the selected marker.
q
Peak Between M3 & M4
— Places the selected marker at the fre-
quency with maximum amplitude value between marker M1 and M2.
q
Valley Between M3 & M4
— Places the selected marker at the fre-
quency with minimum amplitude value between marker M1 and M2.
q
Back
— Returns to the previous menu level.
q
Regular Marker
— Measures the signal level at the point of the marker in
the unit type selected in the Amplitude - Units menu. When the regular
marker option is selected, all markers are regular markers.
q
Noise Marker
— Measures noise level normalized to a 1 Hz bandwidth.
The unit of measure is dBm/Hz only. When Noise Marker is selected, the
detection type is automatically changed to RMS average. When the Noise
Marker option is selected, all markers are noise markers.
q
All Off
— Turns off all markers.
2-56
Chapter 2 Functions and Operations
Summary of Contents for Cell Master MT8212B
Page 3: ......
Page 5: ......
Page 222: ...12 4 Chapter 12 GPS Feature Figure 12 3 Saved GPS Location Information...
Page 231: ...Chapter 13 CDMA Measurement 13 9 Figure 13 5 CDMA Display with Markers...
Page 255: ...Chapter 18 EVDO Mode 18 5...