q
Method
— Allows selection of either % of power or dB Down.
q
%
— Allows entry of the desired % of occupied bandwidth to be mea-
sured.
q
dBc
— Allows entry of the desired power level (dBc) to be measured.
q
Measure
— Enables and disables the OBW measurement.
q
Back
— Returns to the previous menu level.
q
Channel Power
— Activates Channel Power measurement. Channel power
is measured in dBm. Channel Power density is measured in dBm/Hz. The
displayed units is determined by the setting of the
Units
soft key in the
AMPLITUDE
menu.
q
Center Freq
- Activates the center frequency function and sets the Cell
Master to the center frequency. A specific center frequency can be en-
tered using the keypad or Up/Down arrow key.
q
Int BW
— Enter the integration bandwidth frequency appropriate for
the application. Integration bandwidth must be at least one tenth of the
channel span.
q
Channel Span
— Sets the channel span to a value appropriate for the
application.
q
Zoom One Channel
— Automatically sets the span to cover one chan-
nel as defined by the selected signal standard.
q
Measure
— Enables and disables the channel power measurement.
q
Back
— Returns to the previous menu level.
q
ACPR
— Accesses a menu of Adjacent Channel Power Ratio measure-
ment options:
q
Center Freq
- Activates the center frequency function and sets the Cell
Master to the center frequency. A specific center frequency can be en-
tered using the keypad or Up/Down arrow key.
q
Main Channel BW
- Sets the bandwidth of the main channel.
q
Adjacent Channel BW
- Sets the bandwidth of the adjacent channel.
q
Channel Spacing
- Sets the channel spacing.
q
Measure
-Enables and disables the ACPR measurement.
q
Back
- Returns to the previous menu.
q
More
— Opens more measurement menus in spectrum analyzer mode.
q
Int. Analysis
— Opens the interference analysis measurement menu.
q
Set IA Freq.
— Set the interference analysis frequency from 9 kHz
to 3000 MHz to measure the interference.
q
Measure
— Measures the interference.
q
IA Freq. To Center
— Set the interference analysis frequency to
the center of the interference frequency.
q
IA Freq as Marker M1
— Set the interference analysis frequency as
marker M1.
q
Back
— Returns to the previous menu.
Chapter 2 Functions and Operations
2-21
Summary of Contents for Cell Master MT8212B
Page 3: ......
Page 5: ......
Page 222: ...12 4 Chapter 12 GPS Feature Figure 12 3 Saved GPS Location Information...
Page 231: ...Chapter 13 CDMA Measurement 13 9 Figure 13 5 CDMA Display with Markers...
Page 255: ...Chapter 18 EVDO Mode 18 5...