Reference Data
Coaxial Cable Technical Data
Table A-1 provides a standard listing of common coaxial cables.
A-1
Mfgr.
Cable
Prop.
Vel
Freq 1 Loss 1 Freq 2 Loss 2 Freq 3 Loss 3
Andrew
FSJ1-50A (6 GHz)
0.84
1000
0.196
2500
0.313
6000
0.532
Andrew
FSJ2-50 (6 GHz)
0.83
1000
0.133
2500
0.223
6000
0.374
Andrew
FSJ4-50B (6 GHz)
0.81
1000
0.118
2500
0.201
6000
0.348
Andrew
EFX2-50 (6 GHz)
0.85
1000
0.121
2500
0.202
6000
0.341
Andrew
LDF1-50 (6 GHz)
0.86
6000
0.306
6000
0.306
6000
0.306
Andrew
LDF2-50 (6 GHz)
0.88
6000
0.323
6000
0.323
6000
0.323
Andrew
LDF4-50A (6 GHz)
0.88
1000
0.073
2500
0.121
6000
0.218
Andrew
HJ4-50 (6 GHz)
0.914
1000
0.092
2500
0.156
6000
0.257
Andrew
HJ4.5-50 (6 GHz)
0.92
1000
0.054
2500
0.089
6000
0.148
Andrew
AVA5-50 7/8
0.91
1000
0.038
2000
0.055
2500
0.063
Andrew
AVA7-50 1-5/8
0.92
1000
0.022
2000
0.034
2500
0.038
Andrew
EFX2-50
0.85
1000
0.121
2000
0.177
2500
0.202
Andrew
FLC 12-50J
0.88
1000
0.075
2000
0.11
2500
0.134
Andrew
FLC 38-50J
0.88
1000
0.115
2000
0.169
2500
0.19
Andrew
FLC 78-50J
0.88
1000
0.041
2000
0.061
2500
0.072
Andrew
FLC 114-50J
0.88
1000
0.033
2000
0.05
2500
0.059
Andrew
FLC 158-50J
0.88
1000
0.025
2000
0.038
2500
0.042
Andrew
FSJ1-50A
0.84
1000
0.196
2000
0.285
2500
0.313
Andrew
FSJ2-50
0.83
1000
0.133
2000
0.196
2500
0.223
Andrew
FSJ4-50B
0.81
1000
0.118
2000
0.176
2500
0.201
Andrew
HJ4-50
0.91
1000
0.092
2000
0.137
2500
0.156
Andrew
HJ4.5-50
0.92
1000
0.054
2000
0.079
2500
0.089
Andrew
HJ5-50
0.916
1000
0.042
2000
0.063
2500
0.071
Andrew
HJ7-50A
0.921
1000
0.023
2000
0.034
2500
0.039
Andrew
HJ12-50
0.931
1000
0.019
2000
0.029
2000
0.029
Andrew
HL4RP-50A
0.88
1000
0.074
2000
0.109
2500
0.123
Andrew
LDF4-50A
0.88
1000
0.073
2000
0.107
2500
0.12
Andrew
LDF4.5-50
0.89
1000
0.054
2000
0.08
2500
0.091
Andrew
LDF5-50A
0.89
1000
0.041
2000
0.061
2500
0.07
Andrew
LDF5-50B
0.91
1000
0.041
2000
0.061
2500
0.07
Andrew
LDF6-50
0.89
1000
0.028
2000
0.042
2500
0.048
Andrew
LDF7-50A
0.88
1000
0.024
2000
0.037
2500
0.043
Andrew
LDF12-50
0.88
1000
0.021
2000
0.033
2000
0.033
Andrew
VXL5-50 7/8
0.88
1000
0.045
2000
0.066
2500
0.075
Andrew
VXL6-50 1-1/4
0.88
1000
0.032
2000
0.048
2500
0.055
Andrew
VXL7-50 1-5/8
0.88
1000
0.024
2000
0.037
2500
0.043
Belden
RG-8/8A
0.86
1000
0.132
2000
0.33
2500
0.22
Belden
RG-9/9A
0.659
1000
0.289
1000
0.289
1000
0.289
Table A-1.