q
A
®
B — Moves the currently displayed trace into the Trace B
buffer.
q
A - B
®
A — Subtracts Trace B from Trace A and displays the result
as Trace A.
q
A + B
®
A — Adds Trace B to Trace A and displays the result as
Trace A.
q
Calibrate TM — Calibrates the Cell Master for transmission measure-
ments.
MARKER
Pressing
MARKER
on the data keypad in Transmission Measurement mode ac-
tivates a menu for the six different markers. Use the corresponding soft key to
select the desired marker. Then use the marker second level menu to turn the
markers on or off, and to edit marker parameters and values.
q
M1
— Selects the M1 marker parameter and opens the Markers second level
menu with M1 highlighted.
q
On/Off
— Turns the selected marker on or off.
q
Edit
— Opens the selected marker parameter for data entry. Enter the de-
sired marker frequency using the keypad or Up/Down arrow key. Select
the
GHz
,
MHz
,
kHz
, or
Hz
soft key to accept the marker frequency input.
q
Delta (Mx-M1)
— Displays delta frequency and amplitude for the selected
marker Mx (M2, M3 or M4) with respect to the M1 marker.
q
Marker To Peak
— Places the selected marker at the maximum amplitude
of a trace (M1 - M4 only).
q
Marker Freq To Center
— Makes the center frequency equal to the fre-
quency of the selected marker.
q
Back
— Returns to the previous menu level.
NOTE: The markers second-level menu above is identical for markers M2-M4.
q
M2
— Selects the M2 marker parameter and opens the Markers second level
menu with M2 highlighted.
q
M3
— Selects the M3 marker parameter and opens the Markers second level
menu with M3 highlighted.
q
M4
— Selects the M4 marker parameter and opens the Markers second level
menu with M4 highlighted.
q
All Off
— Turns off all markers.
q
More
— Press to access additional marker functions:
q
M5
— Selects the M5 marker parameter and opens the M5 marker second
level menu with M5 highlighted.
q
On/Off
— Turns the selected marker on or off.
q
Edit
— Opens the selected marker parameter for data entry. Enter the
desired marker frequency using the keypad or Up/Down arrow key.
Select the
GHz
,
MHz
,
kHz
, or
Hz
soft key to accept the marker fre-
quency input.
q
Marker Freq To Center
— Makes the center frequency equal to the
frequency of the selected marker.
Chapter 2 Functions and Operations
2-43
Summary of Contents for Cell Master MT8212B
Page 3: ......
Page 5: ......
Page 222: ...12 4 Chapter 12 GPS Feature Figure 12 3 Saved GPS Location Information...
Page 231: ...Chapter 13 CDMA Measurement 13 9 Figure 13 5 CDMA Display with Markers...
Page 255: ...Chapter 18 EVDO Mode 18 5...