q
Peak Between M1& M2
— Places the selected marker at the frequency
with maximum amplitude value between marker M1 and M2.
q
Valley Between M1 & M2
— Places the selected marker at the fre-
quency with minimum amplitude value between marker M1 and M2.
q
Back
— Returns to the previous menu level.
NOTE: If markers M1 and/or M2 are off, the Peak and Valley functions above
are executed across the entire span.
q
M6
— Selects the M6 marker parameter and opens the M6 marker second
level menu with M6 highlighted.
q
On/Off
— Turns the selected marker on or off.
q
Edit
— Opens the selected marker parameter for data entry. Enter the
desired marker frequency using the keypad or Up/Down arrow key.
Select the
GHz
,
MHz
,
kHz
, or
Hz
soft key to accept the marker fre-
quency input.
q
Marker Freq To Center
— Makes the center frequency equal to the
frequency of the selected marker.
q
Peak Between M3 & M4
— Places the selected marker at the fre-
quency with maximum amplitude value between marker M1 and M2.
q
Valley Between M3 & M4
— Places the selected marker at the fre-
quency with minimum amplitude value between marker M1 and M2.
q
Back
— Returns to the previous menu level.
q
Regular Marker
— Measures the signal level at the point of the marker in
the unit type selected in the Amplitude - Units menu. When the regular
marker option is selected, all markers are regular markers.
q
Noise Marker
— Measures noise level normalized to a 1 Hz bandwidth.
The unit of measure is dBm/Hz only. When Noise Marker is selected, the
detection type is automatically changed to RMS average. When the Noise
Marker option is selected, all markers are noise markers.
q
All Off
— Turns off all markers.
q
Back
— Returns to the previous menu level.
NOTE: If either marker M3 or marker M4 is off, the Peak and Valley functions
above are executed across the entire span.
LIMIT
Pressing
LIMIT
on the data keypad in Transmission Measurement mode acti-
vates a menu of limit-related functions. Use the corresponding soft key to select
the desired limit function. Then use the Up/Down arrow key to change its value,
which is displayed in the message area at the bottom of the display.
q
Single Limit — Sets a single limit value. Menu choices are:
q
On/Off
— Turns the single limit function on or off.
q
Edit
— Allows entry of the limit amplitude using the keypad or Up/Down
arrow key. Press
ENTER
to accept the entered value.
2-44
Chapter 2 Functions and Operations
Summary of Contents for Cell Master MT8212B
Page 3: ......
Page 5: ......
Page 222: ...12 4 Chapter 12 GPS Feature Figure 12 3 Saved GPS Location Information...
Page 231: ...Chapter 13 CDMA Measurement 13 9 Figure 13 5 CDMA Display with Markers...
Page 255: ...Chapter 18 EVDO Mode 18 5...