1-8
Chapter 1 General Information
Bias Tee (Option 10A)
Voltage:
+12 to +24 Vdc (variable in 1V steps)
Power Maximum:
6W, steady state
High Accuracy Power Meter (Option 19, with PSN50 Power Sensor)
Sensor:
Measurement Range:
–30 to +20 dBm
Frequency Range:
50 MHz to 6 GHz
Input Connector:
Type N, male, 50
W
Max Input Without Damage:
+33 dBm, ± 25 VDC
Input Return Loss :
50 MHz to 2 GHz:
³
26 dB
2 GHz to 6 GHz:
³
20 dB
Accuracy:
Total RSS Meas. Uncertainty:
CW signals: ± 0.16 dB (0 to 50
°
C)*
Noise:
20 nW max
Zero Set:
20 nW
Zero Drift:
10 nW max**
Instrumentation Accuracy:
0.00 dB
Sensor Linearity:
± 0.13 dB max
Sensor Cal Factor Uncertainty:
± 0.06 dB
Temperature Compensation:
± 0.06 dB max
Continuous digital modulation uncertainty:
+0.06 dB (+17 to +20 dBm)
System:
Measurement Resolution:
0.01 dB
Offset Range:
± 60dB
Power Requirements:
Supply Voltage:
8 to 18 Vdc
Supply Current:
<100 mA
*Excludes mismatch errors. Excludes noise, zero set, zero drift for levels <-20 dBm. Excludes digital modula-
tion uncertainty b17 and +20 dBm.
**After 30 minute warm-up
Transmission Measurement (Option 21)
RF Source,
Frequency Range:
25 MHz to 3 GHz
Frequency Resolution:
10 Hz
Output Power Level:
–10 dBm typical (up to –90 dBm with external attenuator)
Table 1-1.
Performance Specifications (3 of 7)
Summary of Contents for Cell Master MT8212B
Page 3: ......
Page 5: ......
Page 222: ...12 4 Chapter 12 GPS Feature Figure 12 3 Saved GPS Location Information...
Page 231: ...Chapter 13 CDMA Measurement 13 9 Figure 13 5 CDMA Display with Markers...
Page 255: ...Chapter 18 EVDO Mode 18 5...