Step 1.
Press the
MEAS/DISP
key and then the
BERT
soft key.
Step 2.
Press the
Measure Duration
soft key and use the
Up/Down
arrow key to select
the duration of the measurement, and press
ENTER
. Figure 9-4 displays the E1
measurement display in raw data mode.
Step 3.
To display the measurement data in a histogram format, press the
Display Raw
Data/Histogram
soft key.
Step 4.
Press the
Measure Duration
soft key to set the duration of the measurement, and
press
ENTER
. The maximum measurement duration is two days.
Step 5.
Press the
Time Scale
soft key and use the
Up/Down
arrow key to select the histo-
gram resolution, and press
ENTER
. The maximum time scale is 60 minutes.
NOTE
: The unit sets the histogram display and collects and displays the data
based on the selected time scale. For example, if the time scale is set to 30
minutes, the unit collects and updates the histogram display data every 30 min-
utes. When the time scale is set to Auto, the unit automatically sets the histo-
gram display to collect the data based on the selected measurement duration.
Step 6.
Press the
Start/Stop Measure
soft key to begin the measurement.
Step 7.
Press the
SYS
key, then the
Application Options
and
Log Data
soft keys to save
the data. A message window will display if there is insufficient memory to log
the complete duration. Adjust the Measurement Duration and Time Scale as nec-
essary to log the data.
10-6
Chapter 10 E1 Measurements
Figure 10-4.
E1 BERT Measurement Display
Summary of Contents for Cell Master MT8212B
Page 3: ......
Page 5: ......
Page 222: ...12 4 Chapter 12 GPS Feature Figure 12 3 Saved GPS Location Information...
Page 231: ...Chapter 13 CDMA Measurement 13 9 Figure 13 5 CDMA Display with Markers...
Page 255: ...Chapter 18 EVDO Mode 18 5...