2.8 Setup
The setup for Network Master Gigabit Ethernet module applications is
comprised of several settings, and falls into two categories:
•
Interface setup
Settings for the instruments Ethernet interfaces.
•
Test setup
Settings for supported instrument tests.
Settings are controlled via checkboxes and pop-up dialogs. The specific
settings and how to change them are described in the “Application
Ethernet” and “Application Reflector” sections on pages 3-1 and 4-1,
respectively.
2.8.1 Intelligent
Setup
Some settings depend on other settings. When these settings are changed,
it may be necessary to make additional changes to comply with the
required change.
The Intelligent setup function bridges the two setup categories. Changes to
the Interface setup may require changes to the Test setup and
vice versa.
If a setting change requires additional changes, the Dependency pop-up
dialog is displayed (Figure 2.8.1-1).
Figure 2.8.1-1 Dependency Pop-up
[1] This lists the changes that must be enforced before the setting
changes can be performed. Use the Up and Down arrow keys to
scroll through the list.
[2] Select
the
OK button to change the setting, including all the settings
listed in item 1.
[3] Select
the
Cancel button to cancel the new setting.