3.5 Stimuli
3-33
The Errors/Violations pop-up has five buttons:
•
Clear
This button resets Stimuli settings and switches the pop-up back to
that the one shown in Figure 3.5.1-1.
•
Error/Violations
This button selects the type of inserted error or violation.
•
Error Insertion
This button defines how errors are inserted. Under normal
circumstances, one of following can be inserted:
3
Ether
n
et Applicat
ion
Off
No Errors/Violations are inserted
Manual
Sends selected error or violation each time Apply button pressed
Burst/Sec
Sends burst every 1 s
Burst/10Sec
Sends burst every 10 s
Burst*1E-2 to Burst*1E-7
This Error Insertion setting is only supported by the error type
PRBS Bit Error. When set the transmitted frames contains the
selected ratio of PRBS bit errors.
•
Error Burst Length
This button sets the number of errors per burst.
•
Apply
This button applies the above settings to the. Changes do not take
effect until this button is pressed.
The
Apply button is only enabled during testing. Stimuli changes
made during setup are applied when starting the test, unless Manual
is chosen.