3.8 RFC2544
Tests
3-49
Test Mode pane
[1] Selects RFC2544 test mode
[2] Selects RFC2544 test port(s)
Note
The RFC2544 tests run independently on two ports. If both ports
are selected, the port specific panes display a Port A/B soft key.
Use this soft key to select the port to setup.
3
Ether
n
et Applicat
ion
The RFC2544 Latency test runs in three modes:
Item Description
Router Latency Test
In this test mode, the latency-test sends
ping frames to measure the response time
for router equipment. The line load setup
for the Router Latency Test is measured
in kbps. The maximum line load for the
Router Latency Test is 1000 kbps. The
Network Master can respond to incoming
ping frames, so it can be used to run the
Router Latency Test port to port if
required. The Router Latency Test
supports both IPv4/ICMPv4 and
IPv6/ICMPv6.
Switch Router Test
In this test mode, one Network Master
can switch the data link layer of a switch
or router. Both ports must be active and
linked in this mode. IP and MAC
addresses must be swapped, ensuring
that the switch forwards frames from
port A to port B and
vice versa.
Single Ended
Network Test
This test is used when testing network by
reflecting traffic back to the Network
Master. It requires a device to reflect the
traffic back, such as a second Network
Master in reflector mode.