3.8 RFC2544
Tests
3-43
The only setups at the Slave side are the source addresses and enabling
of Accept incoming End-to-End configuration frames. The complete
RFC2544 setup is transferred from the Master when the test is started.
Note:
When the test is started at the Master, a pop-up on the Slave
indicates that the unit is being remotely controlled and displays a
Disconnect key. The pop-up disappears when the test is completed
or stopped at the Master.
3
Ether
n
et Applicat
ion
When the test is completed, the test results are transferred from the
Slave to the Master where they can be viewed by pressing the Results
Remote/Local soft key.
End-to-End setup
When the End-to-End test mode is selected the End to End pane is
displayed.
Figure 3.8.1-2 RFC2544 Throughput setup screen, End to End pane
When End to End One way test is selected, packets are sent only in one
direction during the test. Use the One way Direction selection to specify
the direction in which packets should be sent.
Test results can be stored on the slave if required. Select the Store
results on slave side checkbox to enable this feature. Results are always
stored on the Master side.