Chapter 3 Application Ethernet
3-44
Duration pane
All RFC2544 tests are executed in steps. A step is a specific combination
of a frame size and line load. During a step, frames with the specified
size are transmitted at the specific line load. The number of steps run
during a test depends on the selected number of frame sizes and line
loads.
The Step Duration time can be set in number of seconds (min.3 seconds)
on the Duration pane. This is approximately the duration of each test
step.
The Test Repetitions field sets the number of times the complete test will
run. The possible setting range is 1 to 1000 times.
Figure 3.8.1-3 RFC2544 Throughput Setup Screen, Duration Pane
Destination pane
The destination setup is similar to that of the Ping test setup. See section
3.6.1 for further details.