
Commands Quick Reference
4
Agilent InfiniiVision 2000 X-Series Oscilloscopes Programmer's Guide
99
:SBUS<n>:SPI:SOURce:C
LOCk <source> (see
page 499
)
:SBUS<n>:SPI:SOURce:C
LOCk? (see
page 499
)
<value> ::= {CHANnel<n> |
EXTernal} for the DSO models
<value> ::= {CHANnel<n> |
DIGital<d>} for the MSO models
<n> ::= 1 to (# analog channels)
in NR1 format
<d> ::= 0 to (# digital channels
- 1) in NR1 format
:SBUS<n>:SPI:SOURce:F
RAMe <source> (see
page 500
)
:SBUS<n>:SPI:SOURce:F
RAMe? (see
page 500
)
<value> ::= {CHANnel<n> |
EXTernal} for the DSO models
<value> ::= {CHANnel<n> |
DIGital<d>} for the MSO models
<n> ::= 1 to (# analog channels)
in NR1 format
<d> ::= 0 to (# digital channels
- 1) in NR1 format
:SBUS<n>:SPI:SOURce:M
ISO <source> (see
page 501
)
:SBUS<n>:SPI:SOURce:M
ISO? (see
page 501
)
<value> ::= {CHANnel<n> |
EXTernal} for the DSO models
<value> ::= {CHANnel<n> |
DIGital<d>} for the MSO models
<n> ::= 1 to (# analog channels)
in NR1 format
<d> ::= 0 to (# digital channels
- 1) in NR1 format
:SBUS<n>:SPI:SOURce:M
OSI <source> (see
page 502
)
:SBUS<n>:SPI:SOURce:M
OSI? (see
page 502
)
<value> ::= {CHANnel<n> |
EXTernal} for the DSO models
<value> ::= {CHANnel<n> |
DIGital<d>} for the MSO models
<n> ::= 1 to (# analog channels)
in NR1 format
<d> ::= 0 to (# digital channels
- 1) in NR1 format
:SBUS<n>:SPI:TRIGger:
PATTern:MISO:DATA
<string> (see
page 503
)
:SBUS<n>:SPI:TRIGger:
PATTern:MISO:DATA?
(see
page 503
)
<string> ::= "nn...n" where n ::=
{0 | 1 | X | $}
<string ::= "0xnn...n" where n
::= {0,..,9 | A,..,F | X | $}
:SBUS<n>:SPI:TRIGger:
PATTern:MISO:WIDTh
<width> (see
page 504
)
:SBUS<n>:SPI:TRIGger:
PATTern:MISO:WIDTh?
(see
page 504
)
<width> ::= integer from 4 to 64
in NR1 format
Table 26 :SBUS<n>:SPI Commands Summary (continued)
Command
Query
Options and Query Returns
Summary of Contents for InfiniiVision 2000 X-Series
Page 1: ...s1 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide...
Page 24: ...24 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide...
Page 38: ...38 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 1 What s New...
Page 48: ...48 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 2 Setting Up...
Page 62: ...62 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 3 Getting Started...
Page 206: ...206 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 8 BUS n Commands...
Page 242: ...242 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 11 DEMO Commands...
Page 250: ...250 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 12 DIGital d Commands...
Page 270: ...270 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 14 DVM Commands...
Page 312: ...312 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 17 HARDcopy Commands...
Page 332: ...332 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 19 MARKer Commands...
Page 416: ...416 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 22 POD Commands...
Page 424: ...424 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 23 RECall Commands...
Page 446: ...446 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 24 SAVE Commands...
Page 588: ...588 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 28 TIMebase Commands...
Page 692: ...692 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 31 WGEN Commands...
Page 758: ...758 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 34 Error Messages...