Commands Quick Reference
4
Agilent InfiniiVision 2000 X-Series Oscilloscopes Programmer's Guide
107
:TIMebase:VERNier {{0
| OFF} | {1 | ON}}
(see
page 584
)
:TIMebase:VERNier?
(see
page 584
)
{0 | 1}
:TIMebase:WINDow:POSi
tion <pos> (see
page 585
)
:TIMebase:WINDow:POSi
tion? (see
page 585
)
<pos> ::= time from the trigger
event to the zoomed view
reference point in NR3 format
:TIMebase:WINDow:RANG
e <range_value> (see
page 586
)
:TIMebase:WINDow:RANG
e? (see
page 586
)
<range value> ::= range value in
seconds in NR3 format for the
zoomed window
:TIMebase:WINDow:SCAL
e <scale_value> (see
page 587
)
:TIMebase:WINDow:SCAL
e? (see
page 587
)
<scale_value> ::= scale value in
seconds in NR3 format for the
zoomed window
Table 35 :TIMebase Commands Summary (continued)
Command
Query
Options and Query Returns
Table 36 General :TRIGger Commands Summary
Command
Query
Options and Query Returns
:TRIGger:FORCe (see
page 592
)
n/a
n/a
:TRIGger:HFReject {{0
| OFF} | {1 | ON}}
(see
page 593
)
:TRIGger:HFReject?
(see
page 593
)
{0 | 1}
:TRIGger:HOLDoff
<holdoff_time> (see
page 594
)
:TRIGger:HOLDoff?
(see
page 594
)
<holdoff_time> ::= 60 ns to 10 s
in NR3 format
:TRIGger:LEVel:ASETup
(see
page 595
)
n/a
n/a
:TRIGger:LEVel:HIGH
<level>, <source>
(see
page 596
)
:TRIGger:LEVel:HIGH?
<source> (see
page 596
)
<level> ::= .75 x full-scale
voltage from center screen in NR3
format.
<source> ::= CHANnel<n>
<n> ::= 1 to (# analog channels)
in NR1 format
:TRIGger:LEVel:LOW
<level>, <source>
(see
page 597
)
:TRIGger:LEVel:LOW?
<source> (see
page 597
)
<level> ::= .75 x full-scale
voltage from center screen in NR3
format.
<source> ::= CHANnel<n>
<n> ::= 1 to (# analog channels)
in NR1 format
Summary of Contents for InfiniiVision 2000 X-Series
Page 1: ...s1 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide...
Page 24: ...24 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide...
Page 38: ...38 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 1 What s New...
Page 48: ...48 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 2 Setting Up...
Page 62: ...62 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 3 Getting Started...
Page 206: ...206 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 8 BUS n Commands...
Page 242: ...242 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 11 DEMO Commands...
Page 250: ...250 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 12 DIGital d Commands...
Page 270: ...270 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 14 DVM Commands...
Page 312: ...312 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 17 HARDcopy Commands...
Page 332: ...332 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 19 MARKer Commands...
Page 416: ...416 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 22 POD Commands...
Page 424: ...424 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 23 RECall Commands...
Page 446: ...446 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 24 SAVE Commands...
Page 588: ...588 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 28 TIMebase Commands...
Page 692: ...692 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 31 WGEN Commands...
Page 758: ...758 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 34 Error Messages...