s
1
447
Agilent InfiniiVision 2000 X-Series Oscilloscopes
Programmer's Guide
25
:SBUS<n> Commands
Control the modes and parameters for each serial bus decode/trigger type.
See:
•
"Introduction to :SBUS<n> Commands"
on page 447
•
"General :SBUS<n> Commands"
on page 449
•
":SBUS<n>:CAN Commands"
on page 452
•
":SBUS<n>:IIC Commands"
on page 469
•
":SBUS<n>:LIN Commands"
on page 479
•
":SBUS<n>:SPI Commands"
on page 493
•
":SBUS<n>:UART Commands"
on page 509
Introduction to
:SBUS<n>
Commands
The :SBUS subsystem commands control the serial decode bus viewing,
mode, and other options.
The following serial bus decode/trigger types are available (see
":TRIGger:MODE"
on page 598).
• CAN (Controller Area Network) triggering
— will trigger on CAN
version 2.0A and 2.0B signals. Setup consists of connecting the
oscilloscope to a CAN signal. Baud rate, signal source, and signal
polarity, and type of data to trigger on can be specified. You can trigger
on CAN data and identifier patterns and you can set the bit sample
point.
• IIC (Inter- IC bus) triggering
— consists of connecting the oscilloscope
to the serial data (SDA) line and the serial clock (SCL) line, then
triggering on a stop/start condition, a restart, a missing acknowledge, or
on a read/write frame with a specific device address and data value.
• LIN (Local Interconnect Network) triggering
— will trigger on LIN sync
break at the beginning of a message frame.You can trigger on Sync
Break, Frame IDs, or Frame IDs and Data.
N O T E
These commands are only valid on oscilloscope models when a serial decode option has
been licensed.
Summary of Contents for InfiniiVision 2000 X-Series
Page 1: ...s1 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide...
Page 24: ...24 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide...
Page 38: ...38 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 1 What s New...
Page 48: ...48 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 2 Setting Up...
Page 62: ...62 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 3 Getting Started...
Page 206: ...206 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 8 BUS n Commands...
Page 242: ...242 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 11 DEMO Commands...
Page 250: ...250 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 12 DIGital d Commands...
Page 270: ...270 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 14 DVM Commands...
Page 312: ...312 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 17 HARDcopy Commands...
Page 332: ...332 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 19 MARKer Commands...
Page 416: ...416 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 22 POD Commands...
Page 424: ...424 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 23 RECall Commands...
Page 446: ...446 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 24 SAVE Commands...
Page 588: ...588 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 28 TIMebase Commands...
Page 692: ...692 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 31 WGEN Commands...
Page 758: ...758 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 34 Error Messages...