:TRIGger Commands
29
Agilent InfiniiVision 2000 X-Series Oscilloscopes Programmer's Guide
607
:TRIGger:GLITch Commands
Table 91 :TRIGger:GLITch Commands Summary
Command
Query
Options and Query Returns
:TRIGger:GLITch:GREat
erthan
<greater_than_time>[s
uffix] (see
page 609
)
:TRIGger:GLITch:GREat
erthan? (see
page 609
)
<greater_than_time> ::=
floating-point number in NR3
format
[suffix] ::= {s | ms | us | ns |
ps}
:TRIGger:GLITch:LESSt
han
<less_than_time>[suff
ix] (see
page 610
)
:TRIGger:GLITch:LESSt
han? (see
page 610
)
<less_than_time> ::=
floating-point number in NR3
format
[suffix] ::= {s | ms | us | ns |
ps}
:TRIGger:GLITch:LEVel
<level> [<source>]
(see
page 611
)
:TRIGger:GLITch:LEVel
? (see
page 611
)
For internal triggers, <level>
::= .75 x full-scale voltage from
center screen in NR3 format.
For external triggers (DSO
models), <level> ::= ±(external
range setting) in NR3 format.
For digital channels (MSO
models), <level> ::= ±8 V.
<source> ::= {CHANnel<n> |
EXTernal} for DSO models
<source> ::= {CHANnel<n> |
DIGital<d>} for MSO models
<n> ::= 1 to (# analog channels)
in NR1 format
<d> ::= 0 to (# digital channels
- 1) in NR1 format
:TRIGger:GLITch:POLar
ity <polarity> (see
page 612
)
:TRIGger:GLITch:POLar
ity? (see
page 612
)
<polarity> ::= {POSitive |
NEGative}
:TRIGger:GLITch:QUALi
fier <qualifier> (see
page 613
)
:TRIGger:GLITch:QUALi
fier? (see
page 613
)
<qualifier> ::= {GREaterthan |
LESSthan | RANGe}
Summary of Contents for InfiniiVision 2000 X-Series
Page 1: ...s1 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide...
Page 24: ...24 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide...
Page 38: ...38 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 1 What s New...
Page 48: ...48 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 2 Setting Up...
Page 62: ...62 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 3 Getting Started...
Page 206: ...206 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 8 BUS n Commands...
Page 242: ...242 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 11 DEMO Commands...
Page 250: ...250 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 12 DIGital d Commands...
Page 270: ...270 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 14 DVM Commands...
Page 312: ...312 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 17 HARDcopy Commands...
Page 332: ...332 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 19 MARKer Commands...
Page 416: ...416 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 22 POD Commands...
Page 424: ...424 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 23 RECall Commands...
Page 446: ...446 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 24 SAVE Commands...
Page 588: ...588 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 28 TIMebase Commands...
Page 692: ...692 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 31 WGEN Commands...
Page 758: ...758 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 34 Error Messages...