MC96FR116C
November, 2018 Rev.1.8
173
BODI3
VDD level indicator 3. After calibration, this flag turns on around 2.2V
only when BODLS[2:0] = 010
B
.
0
VDD level is higher than V
BODI3
1
VDD dropped below V
BODI3
BODI2
VDD level indicator 2. After calibration, this flag turns on around 2.0V
only when BODLS[2:0] = 001
B
.
0
VDD level is higher than V
BODI2
1
VDD dropped below V
BODI2
BODI1
VDD level indicator 1. After calibration, this flag turns on around 1.8V
only when BODLS[2:0] = 000
B
.
0
VDD level is higher than V
BODI1
1
VDD dropped below V
BODI1
CFGCR (Configuration Control Register)
8F
H
7
6
5
4
3
2
1
0
SWRM
-
-
STUE
-
-
SWU
SWR
R/W
-
-
R/W
-
-
R/W
R/W
Initial value : 10
H
SWRM
The monitor of Software reset
0
Software reset was not asserted.
1
Software reset was asserted.
STUE
Configuration/trimming register update is enabled at stop mode.
0
Hardware will not update configuration register at stop mode.
1
Hardware will update configuration register at stop mode.
SWU
Configuration/trimming register update enable with at software
0
Configuration register will not be updated.
1
Configuration register will be updated at once.
SWR
Generate software reset signal.
0
Software reset is not enabled.
1
Software reset is enabled.