Preparations before removing the axis-1 gearbox
Use this procedure to do the necessary preparations, before removing the gearbox.
Note
Action
Decide which calibration routine to use, and
take actions accordingly prior to beginning
the repair procedure.
1
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
2
xx2200001398
Hold the mechanical stop pin in a firm grip,
and remove it by unscrewing the set screw.
3
xx2200001430
Foundry Plus
Remove the axis-1 cable protection plate by
removing the attachment screws.
4
See
Floor-mounted robot: Draining the
Begin draining the axis-1 gearbox.
Note
There will be some oil left in the gear after
draining.
5
Continues on next page
460
Product manual - IRB 6740
3HAC085701-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.9.1 Replacing the axis-1 gearbox