Note
Action
xx2200001468
Lift the balancing device away.
7
Removing the cradle
Note
Action
xx2300000855
Refit the retaining ring previously removed from
the cradle ear.
Note
The retaining rings need to be present to keep
the bearings in place during lift of the cradle.
1
Lifting eye M16: 3HAC14457-4
Fit a lifting eye to each cradle ear.
2
xx2300000856
Roundsling, 0.5 m
Run a roundsling through each lifting eye and at-
tach to an overhead crane.
3
Raise the lifting equipment to secure the weight
of the cradle.
4
Continues on next page
Product manual - IRB 6740
455
3HAC085701-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.9.1 Replacing the axis-1 gearbox
Continued