Note
Action
xx2200001433
Remove the metal clamp at the arm house.
4
xx2200001430
Protection type Foundry Plus
Remove the axis-1 cable protection plates
by removing the attachment screws.
5
Removing the cable harness - upper arm and wrist
These procedures describe how to remove the cable harness in the upper arm and
wrist.
Retrieving access to the wrist cabling
Use this procedure to remove the wrist cover.
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
Continues on next page
308
Product manual - IRB 6740
3HAC085701-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.7.1 Removing the cable harness
Continued
Summary of Contents for OmniCore IRB 6740
Page 1: ...ROBOTICS Product manual IRB 6740 ...
Page 8: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 176: ...This page is intentionally left blank ...
Page 608: ...This page is intentionally left blank ...
Page 638: ...This page is intentionally left blank ...
Page 658: ...This page is intentionally left blank ...
Page 663: ......