Disconnecting the axis-1 and axis-2 motor cables
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
Remove the motor cover by removing the
screws.
2
xx2200001736
Disconnect the power cable connector by
first removing the attachment screw and
then parting the connector.
3
xx2200001737
Disconnect the signal cable connector by
pulling it out.
4
Continues on next page
Product manual - IRB 6740
319
3HAC085701-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.7.1 Removing the cable harness