Note
Action
Brake release tool: 3HAC081310-001
CAUTION
Releasing the brakes on the axis-2 motor
results in weight transfer of upper and
lower arm weight to the inserted lock screw
in the lower arm or to the attached lifting
accessories (whichever is used). If lifting
accessories are used, verify that the lifting
chains and roundslings are stretched by
raising the overhead crane, before releas-
ing the brakes.
3
User instructions are enclosed with the
tool.
xx2100000666
Release the brakes on the motor with the
brake release tool, to unload the weight:
1
Turn off the brake release tool.
2
Connect the tool to the motor power
connector (MP).
3
Release the brakes by turning on the
brake release tool and pressing the
brake release button on the tool.
The power for brake release is only
applied for 180 seconds after activa-
tion.
DANGER
Handling the tool incorrectly will cause
serious injury.
Read and follow enclosed user instructions
for the tool.
WARNING
Electrical damage to the motor may occur
if 24V is supplied to the motor connector
for more than 30 seconds. Use the spe-
cified brake release tool to eliminate the
risk.
Bits extender: 3HAC12342-1
Remove the two lower screws.
4
xx2000000468
Use a bits extender in order to reach the
screws.
Continues on next page
386
Product manual - IRB 6740
3HAC085701-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.8.2 Replacing the axis-2 motor
Continued
Summary of Contents for OmniCore IRB 6740
Page 1: ...ROBOTICS Product manual IRB 6740 ...
Page 8: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 176: ...This page is intentionally left blank ...
Page 608: ...This page is intentionally left blank ...
Page 638: ...This page is intentionally left blank ...
Page 658: ...This page is intentionally left blank ...
Page 663: ......