Note
Action
Person 1, working at the side hole:
Remove the cable harness out from the
wrist.
Tip
This step is best performed by two persons
working together:
•
Person 1: Put one hand inside the
side hole and take a hold of the
cable harness.
•
Person 2: Take a hold on the cable
harness inside the wrist.
•
Together: Move the cable harness
past the axis-5 motor and into the
arm tube.
6
xx2300000035
Person 2, working at the wrist:
xx2300000036
Person 1, working at the side hole:
Remove the cable harness out of the arm
tube, at the back of the upper arm.
Tip
This step is best performed by two persons
working together:
•
Person 1: Put one hand inside the
side hole and take a hold of the
cable harness.
•
Person 2: Take a hold on the cable
harness at the back of the robot.
•
Together: Move the cable harness
out of the arm tube.
7
xx2300000037
Person 2, working at the back:
xx2300000038
Continues on next page
266
Product manual - IRB 6740
3HAC085701-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.5.1 Replacing the arm house cover including the axis-4 cassette sealing
Continued
Summary of Contents for OmniCore IRB 6740
Page 1: ...ROBOTICS Product manual IRB 6740 ...
Page 8: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 176: ...This page is intentionally left blank ...
Page 608: ...This page is intentionally left blank ...
Page 638: ...This page is intentionally left blank ...
Page 658: ...This page is intentionally left blank ...
Page 663: ......