Removing the wrist
Note
Action
xx2300000015
Remove all attachment screws but leave
one.
1
Guide pin, M12x150: 3HAC13056-2
Fit guide pins to the wrist unit and then re-
move the remaining screw.
2
xx2300000016
Bit holder and hexagon bit SW10
Pull out the wrist a bit and bring out the
cabling from the wrist unit.
CAUTION
Make sure that the cabling does not get
damaged.
3
Bit holder dimension: 5/16" (14x18 mm)
xx2200001808
Lift away the wrist.
4
Refitting the wrist
These procedures describes how to refit the wrist.
Preparations before refitting the wrist
Note
Action
Wipe clean all contact surfaces.
1
Continues on next page
290
Product manual - IRB 6740
3HAC085701-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.6.1 Replacing the wrist
Continued