Note
Action
xx2200001918
Align the balancing device link ear with the hole
in the lower arm.
Note
Verify that the link ear is correctly turned.
5
xx2200001917
Lubricate the shaft and place it to the front ear.
Note
Foundry Plus
:
Do not lubricate surfaces where Mercasol is ap-
plied.
6
Dismantle and mounting tool:
3HAC028920-001
Press in the shaft using the dismantle and
mounting tool, according to user instructions en-
closed with the equipment.
7
User instructions are enclosed with
the tool.
xx0900000813
Go to the user instructions enclosed with the
press tool.
DANGER
Handling the tool incorrectly will cause serious
injury.
Read and follow enclosed user instructions for
the tool.
Continues on next page
Product manual - IRB 6740
205
3HAC085701-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the axis-1 cassette sealing
Continued