Note
Action
1 screw: M6 x 8.
xx0300000612
Refit the bottom plate underneath the robot
base by pushing it into the groove and fitting
the attachment screw.
If removed, also refit the rear connector plate.
Note
Direct the bends on the bottom plate down-
wards!
11
•
A: Bottom plate
•
B: Rear connector plate
•
C: Attachment screw
•
D: Groove
CAUTION
The base and axis 1 gearbox weighs 130 kg
+ .
All lifting accessories used must be sized ac-
cordingly!
12
Lift the robot base and gearbox 1 and remove
the base and gear support.
13
See
Orienting and securing the robot
.
Secure the base to the mounting site.
14
See
Replacing the base, including axis
Refit the complete arm system.
CAUTION
This is a complex task to be performed with
utmost care in order to avoid injury or dam-
age!
15
See section
Perform a leak-down test.
16
See
Changing oil, axis-1 gearbox on
.
Refill the gearbox with oil.
17
Pendulum Calibration is described in
Operating manual - Calibration Pendu-
lum
, enclosed with the calibration tools.
Recalibrate the robot.
18
Axis Calibration is described in
ing with Axis Calibration method on
page 315
.
General calibration information is in-
cluded in section
.
DANGER
Make sure all safety requirements are met
when performing the first test run.
19
286
Product manual - IRB 660
3HAC025755-001 Revision: W
© Copyright 2006-2020 ABB. All rights reserved.
4 Repair
4.7.1 Replacing the axis 1 gearbox
Continued
Summary of Contents for IRB 660
Page 1: ...ROBOTICS Product manual IRB 660 ...
Page 8: ...This page is intentionally left blank ...
Page 332: ...This page is intentionally left blank ...
Page 352: ...This page is intentionally left blank ...
Page 354: ...This page is intentionally left blank ...
Page 360: ......
Page 361: ......