Note
Art no.
Spare part no.
Equipment
Content is defined in section
-
Standard toolkit
These procedures include
references to the tools re-
quired.
Other tools and pro-
cedures may be re-
quired. See refer-
ences to these pro-
cedures in the step-
by-step instructions
below.
Removal, upper rod
The procedure below details how to remove the upper rod of the linkage.
Note
Action
Check especially that it is possible to re-
move the lock nut at the link.
Put the robot in a position where it is possible
to reach all parts that shall be removed.
1
xx1000001132
Let the
tilthouse
rest on a workbench, on
some pallets or similar.
This is done in order to prevent the tilthouse
from falling downwards when the upper rod
is removed.
2
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot work-
ing area.
3
Continues on next page