Metal clamp, tilthouse
M
The motor axis 6 is located as shown in the figure below.
xx0600002600
Motor, axis 6
A
Attachment screws and washers
B
Cable gland cover
C
Motor cover
D
Required equipment
Note
Art.no.
Equipment, etc
For spare part no. see:
•
Cable harness, 1-6
Motor, axis 6
-
Gasket
Content is defined in section
.
-
Standard toolkit
These procedures include
references to the tools re-
quired.
Other tools and procedures may
be required. See references to
these procedures in the step-by-
step instructions below.
See chapter
.
Circuit diagram
Removing cable harness, upper end (incl. axis 6)
Use this procedure to remove the cable harness, upper arm (incl. axis 6).
Note
Action
This is done in order to facilitate updating
of the revolution counter.
Move the robot to the calibration position.
1
Continues on next page
Product manual - IRB 660
159
3HAC025755-001 Revision: W
© Copyright 2006-2020 ABB. All rights reserved.
4 Repair
4.3.2 Replacing the cable harness, upper end (incl. axis 6)