Note
Action
xx0600002734
A Block for calibration
B Calibration plate axis 1
Refit the
block for calibration
and the
axis 1
calibration plate
.
16
See
Performing a leak-down test on
.
Perform a leak-down test of the axis 1 gear-
box.
17
See
Changing oil, axis-1 gearbox on
.
Refill the axis 1 gearbox with lubricating oil.
18
Pendulum Calibration is described in
Operating manual - Calibration Pendulum
,
enclosed with the calibration tools.
Recalibrate the robot.
19
Axis Calibration is described in
ing with Axis Calibration method on
page 315
.
General calibration information is included
in section
DANGER
Make sure all safety requirements are met
when performing the first test run.
20
Product manual - IRB 660
171
3HAC025755-001 Revision: W
© Copyright 2006-2020 ABB. All rights reserved.
4 Repair
4.3.3 Replacing the base, including axis 1 gearbox
Continued