Inspection, position switch
The procedure below details how to inspect the position switch, axis 1.
Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the safeguarded
space.
1
Check the position switch!
•
Check that the rollers are easy to push in
and that they roll freely.
2
Check the rail!
•
Check that the rail is firmly attached with
the attachment screws.
3
Check the cams!
•
Check that the rollers have not caused
any impressions on the cams.
•
Check that the cams are clean. Wipe them
if necessary!
•
Check that the set screws holding the
cams in position are firmly attached.
4
Check the protection sheets on axis 1!
•
Check that the three sheets are in position
and not damaged. Deformation can result
in rubbing against the cams!
•
Check that the area inside of the sheets
is clean enough not to interfere with the
function of the position switch.
5
If any damage is detected, the position switch
must be replaced!
6
Product manual - IRB 660
119
3HAC025755-001 Revision: W
© Copyright 2006-2020 ABB. All rights reserved.
3 Maintenance
3.3.10 Inspection, position switch axis 1
Continued
Summary of Contents for IRB 660