Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the safeguarded space.
2
Article number is specified in
quired tools and equipment on
page 120
.
If the lamp is not lit, trace the fault by:
•
inspecting whether the signal lamp is broken.
If so, replace it.
•
inspecting cable connections.
•
measuring the voltage in the connectors of
motor axis 6 (=24V).
•
inspecting the cabling. Replace the cabling if
a fault is detected.
3
Product manual - IRB 660
121
3HAC025755-001 Revision: W
© Copyright 2006-2020 ABB. All rights reserved.
3 Maintenance
3.3.11 Inspecting the signal lamp (option)
Continued