Note
Action
Disconnect the power cable connector by
removing the attachment screw.
4
Disconnect the signal cable connector.
5
Remove the cable bracket by removing the
screws.
6
Remove the motor cables.
7
Disconnecting the axis-6 motor cables
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
xx2000000376
Unscrew the attachment screws and re-
move the motor cover.
2
xx2000000375
Remove the connector bracket.
3
Disconnect the motor cables.
4
Continues on next page
218
Product manual - IRB 5720
3HAC079195-001 Revision: A
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.5.1 Replacing the arm house cover including the axis-4 cassette sealing
Continued