Note
Action
xx2100002161
Connect the battery cable to the SMB unit.
Make sure the lock snaps into place during refit-
ting.
Note
Make sure that the connector is assembled in
the correct direction according to its keying.
5
xx2100002162
Connect all connectors to the SMB board:
•
R1.SMB1-3, R1.SMB4-6 and R2.SMB
•
If cabling is used for 7th axis (option), refit
the connector R1.SMB7
6
Refitting the electronic box
Note
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the unit
read the safety information in section
1
Gasket for cover, electronics:
3HAC073671-001
Check the electronic box gasket.
Replace if damaged.
2
Torx pan head screw: M6x60 (5
pcs)
Refit the electronic box with the attachment screws.
3
Tightening torque: 10 Nm.
xx2100002134
Continues on next page
Product manual - IRB 5720
317
3HAC079195-001 Revision: A
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.7.4 Replacing the SMB unit
Continued