5.4 Axes 1 and 2
5.4.1 Replacing the axis-1 cassette sealing
Location of the cassette sealing
The arm house cover including the cassette sealing is located as shown in the
figure.
xx2100002220
Summary of the replacement procedure
This is a brief summary of the replacement procedure, containing the major actions
to be performed.
1 Remove the cable harness from the base.
2 Remove the sealing ring and protection tube from the frame.
3 Replace the cassette sealing.
Required spare parts
Note
The spare part numbers that are listed in the table can be out of date. See the
latest spare parts of the IRB 5720 via myABB Business Portal,
.
Level
Note
Article number
Spare part
L2
3HAC070194-013
Cassette sealing
Continues on next page
198
Product manual - IRB 5720
3HAC079195-001 Revision: A
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.4.1 Replacing the axis-1 cassette sealing
Summary of Contents for IRB 5720
Page 1: ...ROBOTICS Product manual IRB 5720 ...
Page 8: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 186: ...This page is intentionally left blank ...
Page 580: ...This page is intentionally left blank ...
Page 604: ...This page is intentionally left blank ...
Page 609: ......