Start-up 41
06
T16 Scale
Defines the reference
multiplier/actual value divisor for
the adapter module.
Note
: The parameter is effective
only when
• Transparent 16 profile is
selected
• drive is using the native
communication profile (for
example, DCU or FBA)
• a 16-bit transparent
Reference 1/Actual value 1 is
used.
With an ACS355 drive, the speed
reference from the PLC is
multiplied by the value of this
parameter plus one. For example,
if the parameter has a value of 99
and a reference of 1000 is given by
the master, the reference will be
multiplied by 99 +1 = 100 and
forwarded to the drive as 100000.
According to the DCU profile, this
value is interpreted as a reference
of 100 rpm in the drive.
With ACSM1, ACS850, ACQ810
and ACS880, setting this
parameter to 65535 provides the
approximation of 1
≈
1 rpm.
99
0…65535
Reference multiplier/actual value
divisor
No. Name/Value
Description
Default
Summary of Contents for FPBA-01 PROFIBUS DP
Page 4: ......
Page 10: ...10 Table of contents Document library on the Internet 195 ...
Page 20: ...20 About the manual ...
Page 26: ...26 Overview of the PROFIBUS network and the FPBA 01 module ...
Page 30: ...30 Mechanical installation ...
Page 91: ...Start up 91 8 Click Properties Network Settings and set baud rate ...
Page 98: ...98 Start up ...
Page 118: ...118 Communication profiles ...
Page 178: ...178 Diagnostics ...
Page 182: ...182 Technical data ...