106 Communication profiles
10
1
Actual frequency or
speed value equals
or is greater than
supervision limit.
Target position
reached
0
Actual frequency or
speed value is
within supervision
limit.
Not at target
position
11
1
Vendor-specific bit
as defined by
PROFIdrive
parameter
939
Homing procedure
was executed and is
valid.
0
No valid home
position available
12
1
Vendor-specific bit
as defined by
PROFIdrive
parameter
940
Traversing task
acknowledgement
(0
→
1)
0
13
1
Vendor-specific bit
as defined by
PROFIdrive
parameter
941
Drive stopped.
0
Drive moving.
Traversing task is
executed (n <> 0).
14
Vendor-specific bit as defined by
PROFIdrive parameter
942
15
Vendor-specific bit as defined by
PROFIdrive parameter
943
Bit
Name
Value STATE/Description
Speed control
mode
Positioning mode