124 Communication protocol
1
Station_Status_2
2
Station_Status_3
3
Diag.Master_Add
The address of the master that parameterized this slave
4…5
Ident_Number
(for FPBA-01:
0959h
)
6
2)
Ext_Diag_Data (0x02) (DP-V0 only)
The number of bytes (including this byte) reserved for Extended
Diagnosis
x 0 x x x 1 x x
Diag.Prm_Req
(Set by Slave)
Slave requires re-configuration
and re-parameterization
Diag.Stat_Diag
(Set by Slave)
Static diagnosis. Slave
(temporarily) unable to provide
valid data.
Always set to 1 by slave
Diag.WD_On
(Set by Slave)
Watchdog on
Diag.Freeze_Mode
(Set by Slave) Freeze
command received by slave
Diag.Sync_Mode
(Set by Slave)
Sync command received by
slave
Reserved
Diag.Deactivated
(Set by Master, reset by Slave)
Slave is inactive
MSB LSB
x 0 0 0 0 0 0 0
MSB LSB
Reserved
Diag.Ext_Diag_Overflow
(Set by slave)